-\chapter*{Electron Gun Control Circuit}
+\chapter*{Appendix - Electron Gun Control Circuit}
The control circuit diagram for the electron gun is shown in Figure \ref{electron_gun.pdf}. The wiring of the circuit, including resistors and potentiometers, was incoroprated into a single box, with external connections available for the power supplies, ammeters, electron gun, and sample holder. Both the components and operation of this circuit are straightforward; we will give a brief overview here for completeness.
\end{itemize}
\begin{landscape}
\begin{center}
- \includegraphics[scale=0.80]{/home/sam/Documents/University/honours/thesis/figures/electron_gun.pdf}
+ \includegraphics[scale=0.80]{figures/egun/electron_gun.pdf}
\captionof{figure}{Circuit Diagram for Electron Gun Control}
\label{electron_gun.pdf}
\end{center}
+
+\subsection{The Ammeters}
+
+An ideal ammeter has no input resistance. In reality, it is not the current that is measured, but the voltage accross a fixed input resistor. This voltage can either be amplified, or the resistance increased, for measuring a smaller current.
+
+The 602 and 610B electrometers both provide a large range of scales and amplifier settings for current measurement. Using a low scale setting increases the input impedance, which increases the potential drop accross the ammeter. However, using a large amplifier gain increases noise; hence there is a trade off. For the 602 and 610B electrometers, a significant drift (typical +5\% of scale in 10min) in the zero level was also observed at high amplifier gains, whilst low gains appeared more stable (+10\% noted after 2 days).
\end{landscape}