X-Git-Url: https://git.ucc.asn.au/?a=blobdiff_plain;f=research%2FTCS%2F2012-08-09%2F152654.dat;h=cced300bbd2922ace56fc9fa9b99d032e12ac231;hb=31db1c97b7be5825cbb0a2e71b9df47757668d76;hp=2e4d4fcd709fa3009a516528eb83ed41f2b2eb31;hpb=fa9991133934218ce1b370ba331dd6260851940d;p=matches%2Fhonours.git diff --git a/research/TCS/2012-08-09/152654.dat b/research/TCS/2012-08-09/152654.dat index 2e4d4fcd..cced300b 100644 --- a/research/TCS/2012-08-09/152654.dat +++ b/research/TCS/2012-08-09/152654.dat @@ -12,7 +12,7 @@ # Initial Voltage = Sweep # Heating Current = 1.141 # Heating Voltage = 1.45 -# Chamber Pressure = 4.30e-8 +# Chamber Pressure = 5e-8 # 610B Zero = 0.00 # 602 Zero = 0.00 # 610B Scale = 1e-7 x 0.03 @@ -25,7 +25,7 @@ # ADC Regulator = 3.30 # Sample = Au on Si (60s 3.1A + 120 3.2A + 300s 3.5A ~1e-7mbar) # Title = Au on Si (8 min) -# Comment = First sample. Original sputtering gold ball fell off filament; used new filament. Noted increase in emission current when sputtering filament turned on. Now recording emission current with time for fixed initial energy, to determine the trend. Filament tuinutes ago. +# Comment = First sample. Original sputtering gold ball fell off filament; used new filament. Noted increase in emission current when sputtering filament turned on. Now recording emission current with time for fixed initial energy, to determine the trend. Filament turned off about 3-5 minutes ago. # Data = time DAC ADC4(Is) ADC4_sigma ADC5(Ie) ADC5_sigma # Parameters last checked = 2012-08-09 15:26:54.113460 @@ -2877,3 +2877,27 @@ 1987.21172357 1000 433.63 241.9 951.26 86.15 1987.90766048 1000 433.3 242.58 951.60 85.81 1988.60171461 1000 425.18 243.26 951.66 85.91 +1989.29572558 1000 426.69 242.56 954.40 85.69 +1989.98979855 1000 429.1 243.50 951.70 85.80 +1990.68779445 1000 423.55 241.79 952.18 86.19 +1991.3837049 1000 421.14 242.3 952.72 86.18 +1992.07968545 1000 429.33 242.88 950.30 86.33 +1992.77821469 1000 430.33 242.6 951.71 86.0 +1993.47421908 1000 430.74 241.9 951.45 86.4 +1994.1716876 1000 422.84 242.40 951.48 86.26 +1994.87171054 1000 424.25 243.21 952.93 85.46 +1995.56970048 1000 420.70 240.71 951.9 86.32 +1996.26572156 1000 424.72 243.86 951.97 85.86 +1996.96175551 1000 430.24 241.21 951.14 86.26 +1997.6577332 1000 429.85 242.76 951.49 86.4 +1998.35372949 1000 428.30 245.11 951.43 86.28 +1999.05459189 1000 425.85 239.97 951.35 86.41 +1999.75573397 1000 422.83 243.11 951.39 86.21 +2000.4537456 1000 425.59 241.86 952.9 86.32 +2001.14973474 1000 422.36 242.7 951.31 86.27 +2001.845716 1000 424.85 241.93 950.83 86.49 +2002.54370189 1000 434.9 241.90 951.32 86.12 +2003.24371886 1000 431.25 240.95 949.47 86.93 +# Recieved KILL signal. +# Reason: Need to take some sweeps of the sample. Results show decrease in emission current was observed before any sputtering had been done; can't tell if decrease is due to post-sputtering system relaxation, or the "normal" decrease. Might repeat this test tomorrow. +# File closed at 2012-08-09 16:01:40.877653