Use experiment folders instead of chdir
[matches/MCTX3420.git] / notes / sensors notes - justin.txt
1 PRESSURE SENSORS
2
3 -       A cheap, pretty good pressure sensor in the range required is the MPX2202 manufactured by Freescale (costs about $15).
4 -       For the system several will be needed? One or two inside the box, maybe a couple in the piping/pneumatics system.
5 -       Sensor has 3 used pins: supply voltage, ground and output voltage, and one unused.
6 -       Pressure is measured by the sensor and given as a scaled linear output voltage.
7 -       Range of 0-40mV over 0-200kPa.
8 -       Most Freescale sensors have analog output as far as I can tell.
9 -       More expensive sensors are more accurate (with less error), which might be necessary for the project. 
10 -       Honeywell make the Truestability series which cost around $35. 
11 -       These have an amplified analog output, and resolution of 0.03%.
12 -       Output voltage range is from 0 to the supply voltage (either 3.3V or 5.0V)
13 -       Sensor has 3 used pins: supply voltage, ground and output voltage, and 4/8 pins total
14 -       Pressure sensors which don\81ft have pins (i.e. plug in via cables) are generally much more expensive and heavy-duty
15
16 STRAIN GAUGES
17
18 -       Cheap strain gauges are available from Omega ($30-40 for a pack of 5)
19 -       Input/output varies but it is generally a pair of solder pads or input leads. 
20 -       Voltage is applied to the input and a small voltage is read from the output, proportional to the strain.
21 -       Analog output usually in the millivolt range.
22 -       Number of leads/solder pads can vary, but most common is just one input wire and one output wire.
23 -       Multiple strain gauges can be connected to a single \81epad\81f.
24 -       For the coke can we shouldn\81ft need more than one or two gauges (and maybe one to measure strain on the box for safety?).
25 -       Micron also make strain gauges.
26 -       Input and output are thin 1.5cm leads or small contact pads. Same type of analog, low voltage output.
27 -       One input lead & one output lead.
28 -       Strain gauges have different shapes (bar, U-shape, M-shape) which might change the number of wires etc, but it depends on what the sensors team chooses.
29
30 REGULATORS
31
32 -       Electronic pressure regulators are made by Parker.
33 -       Require 12-24V supply voltage, 0-5V input voltage, and 0-5V output voltage.
34 -       Electrical connector has 8 contact pins: 5 for input, 2 for output, and one unused.
35 -       Pins are absolute zero control, supply voltage, setpoint, valve current, signal common, pressure output and valve test voltage output.
36 -       Emerson also make regulators that can accept both analog and digital inputs from a computer, and have can give an analog or digital output (with a single cable).
37 -       These are more expensive though and I'm not sure what connector the cable has.