//==================================\r
//= INTERNAL FUNCTIONS =\r
//==================================\r
-\r
-\r
-/**\r
- * \fn int Ext2_int_GetInode(tVFS_Node *Node, tExt2_Inode *Inode)\r
- * \brief Gets the inode descriptor for a node\r
- * \param Node node to get the Inode of\r
- * \param Inode Destination\r
- */\r
-int Ext2_int_GetInode(tVFS_Node *Node, tExt2_Inode *Inode)\r
-{\r
- return Ext2_int_ReadInode(Node->ImplPtr, Node->Inode, Inode);\r
-}\r
-\r
/**\r
* \fn int Ext2_int_ReadInode(tExt2_Disk *Disk, Uint InodeId, tExt2_Inode *Inode)\r
* \brief Read an inode into memory\r
*/\r
-int Ext2_int_ReadInode(tExt2_Disk *Disk, Uint InodeId, tExt2_Inode *Inode)\r
+int Ext2_int_ReadInode(tExt2_Disk *Disk, Uint32 InodeId, tExt2_Inode *Inode)\r
{\r
int group, subId;\r
\r
- //LogF("Ext2_int_ReadInode: (Disk=%p, InodeId=%i, Inode=%p)", Disk, InodeId, Inode);\r
//ENTER("pDisk iInodeId pInode", Disk, InodeId, Inode);\r
\r
if(InodeId == 0) return 0;\r
Disk->Groups[group].bg_inode_table * Disk->BlockSize + sizeof(tExt2_Inode)*subId,\r
sizeof(tExt2_Inode),\r
Inode);\r
+ \r
+ //LEAVE('i', 1);\r
+ return 1;\r
+}\r
+\r
+/**\r
+ * \brief Write a modified inode out to disk\r
+ */\r
+int Ext2_int_WriteInode(tExt2_Disk *Disk, Uint32 InodeId, tExt2_Inode *Inode)\r
+{\r
+ int group, subId;\r
+ ENTER("pDisk iInodeId pInode", Disk, InodeId, Inode);\r
+ \r
+ if(InodeId == 0) return 0;\r
+ \r
+ InodeId --; // Inodes are numbered starting at 1\r
+ \r
+ group = InodeId / Disk->SuperBlock.s_inodes_per_group;\r
+ subId = InodeId % Disk->SuperBlock.s_inodes_per_group;\r
+ \r
+ LOG("group=%i, subId = %i", group, subId);\r
+ \r
+ // Write Inode\r
+ VFS_WriteAt(Disk->FD,\r
+ Disk->Groups[group].bg_inode_table * Disk->BlockSize + sizeof(tExt2_Inode)*subId,\r
+ sizeof(tExt2_Inode),\r
+ Inode);\r
+ \r
+ LEAVE('i', 1);\r
return 1;\r
}\r
\r
Uint64 Ext2_int_GetBlockAddr(tExt2_Disk *Disk, Uint32 *Blocks, int BlockNum)\r
{\r
Uint32 *iBlocks;\r
+ int dwPerBlock = Disk->BlockSize / 4;\r
+ \r
// Direct Blocks\r
if(BlockNum < 12)\r
return (Uint64)Blocks[BlockNum] * Disk->BlockSize;\r
VFS_ReadAt(Disk->FD, (Uint64)Blocks[12]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
\r
BlockNum -= 12;\r
- if(BlockNum < 256) {\r
+ if(BlockNum < dwPerBlock)\r
+ {\r
BlockNum = iBlocks[BlockNum];\r
free(iBlocks);\r
return (Uint64)BlockNum * Disk->BlockSize;\r
}\r
\r
+ BlockNum -= dwPerBlock;\r
// Double Indirect Blocks\r
- if(BlockNum < 256*256)\r
+ if(BlockNum < dwPerBlock*dwPerBlock)\r
{\r
VFS_ReadAt(Disk->FD, (Uint64)Blocks[13]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
- VFS_ReadAt(Disk->FD, (Uint64)iBlocks[BlockNum/256]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
- BlockNum = iBlocks[BlockNum%256];\r
+ VFS_ReadAt(Disk->FD, (Uint64)iBlocks[BlockNum/dwPerBlock]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
+ BlockNum = iBlocks[BlockNum%dwPerBlock];\r
free(iBlocks);\r
return (Uint64)BlockNum * Disk->BlockSize;\r
}\r
+ \r
+ BlockNum -= dwPerBlock*dwPerBlock;\r
// Triple Indirect Blocks\r
VFS_ReadAt(Disk->FD, (Uint64)Blocks[14]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
- VFS_ReadAt(Disk->FD, (Uint64)iBlocks[BlockNum/(256*256)]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
- VFS_ReadAt(Disk->FD, (Uint64)iBlocks[(BlockNum/256)%256]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
- BlockNum = iBlocks[BlockNum%256];\r
+ VFS_ReadAt(Disk->FD, (Uint64)iBlocks[BlockNum/(dwPerBlock*dwPerBlock)]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
+ VFS_ReadAt(Disk->FD, (Uint64)iBlocks[(BlockNum/dwPerBlock)%dwPerBlock]*Disk->BlockSize, Disk->BlockSize, iBlocks);\r
+ BlockNum = iBlocks[BlockNum%dwPerBlock];\r
free(iBlocks);\r
return (Uint64)BlockNum * Disk->BlockSize;\r
}\r