 \subsection{Safety Mechanisms}
 
-Given the inexperienced nature of the software team, the limited development time, and the unclear specifications, it is not wise to trust safety aspects of the system to software alone. It should also be mentioned that the correct functioning of the system is reliant not only upon the software written during this project, but also the many libraries which are used, and the operating system under which it runs. We found during development that many of the mechanisms for controlling BeagleBone hardware are unreliable and have unresolved issues. We attempted to incorporate safety mechanisms into the software wherever possible.
+Given the inexperienced nature of the software team, the limited development time, and the unclear specifications, it is not wise to trust safety aspects of the system to software alone. It should also be mentioned that the correct functioning of the system is reliant not only upon the software written during this project, but also the many libraries which are used, and the operating system under which it runs. We found during development that many of the mechanisms for controlling BeagleBone hardware are unreliable and have unresolved issues; see the project wiki pages\cite{mctx3420_wiki} for more information. We attempted to incorporate safety mechanisms into the software wherever possible.
 
-Sensors and Actuators should define an initialisation and cleanup function. For an actuator (eg: the pressure regulator), the cleanup function must set the actuator to a predefined safe value (in the case of pressure, atmospheric pressure) before it can be deinitialised. In the case of a software error or user defined emergency, the \verb/Fatal/ function can be called from any point in the software; this will lead to the cleanup functions of devices being called, which will in turn lead to the pressure being set to a safe value. The cleanup functions will also be called if the software exits unexpectedly.
+Sensors and Actuators should define an initialisation and cleanup function. For an actuator (eg: the pressure regulator), the cleanup function must set the actuator to a predefined safe value (in the case of pressure, atmospheric pressure) before it can be deinitialised. In the case of a software error or user defined emergency, the \verb/Fatal/ function can be called from any point in the software; this will lead to the cleanup functions of devices being called, which will in turn lead to the pressure being set to a safe value. 
 
 Sensors and Actuators are designed to include a \verb/sanity/ function which will check a reading or setting is safe respectively. These checks occur whenever a sensor value is read or an actuator is about to be set. In the case of a sensor reading failing the sanity check, \verb/Fatal/ is called immediately and the software shuts down the experiment. In the case of an actuator being set to an unsafe value the software will simply refuse to set the value.
 