1 # File opened at 2012-09-04 12:18:01.254031
2 # aquire[DAC_Settle] = 0.0
3 # aquire[open_files] = [<open file '2012-09-04/121801.dat', mode 'w' at 0x7f4949655660>]
4 # aquire[DAC_Sweep] = 0.0 + 50.0*int(step)
5 # aquire[ADC_Averages] = 2000
6 # aquire[start_date] = 2012-08-30
7 # Parameters:
8 # Accelerating Voltage = 38.4
9 # Focus Voltage = -0.112
10 # Deflection Voltage = 1.348
11 # Venault Voltage = 12.08
12 # Initial Voltage = sweep
13 # Heating Current = 1.141
14 # Heating Voltage = 1.163 (* 1.50 at P.S*)
15 # Chamber Pressure = 2.72e-8
16 # 610B Zero = 0.92
17 # 602 Zero = -0.01
18 # 610B Scale = 1e-7 x 0.03
19 # 602 Scale = 1e-5 x 0.3
20 # 602 0.1 Battery = 8.50
21 # 602 0.03 Battery = 8.12
22 # 602 0.01 Battery = 8.40
23 # 602 0.003 Battery = 8.45
24 # 602 0.001 Battery = 8.28
25 # ADC Regulator = 3.30
26 # Sample = Au on Si (95min 3.5A e-8mbar)
27 # Sample Angle = 136
28 # Title = More sweeps
29 # Comment = Still 2000 averages, but steps of 50 counts
30 # Data = time DAC ADC4 ADC4_sigma ADC5 ADC5_sigma ADC0 ADC0_sigma
31 # Parameters last checked = 2012-08-30 11:10:21.418528
32
33 # Experiment 2012-09-04 12:18:01.255040
34 # Polling for Nones.
35
36 # Data:
37 # time  DAC     ADC4    ADC5    ADC0
38 5.10067749023   0       146.62  357.12  544.94  80.5    535.99  0.3
39 15.0364420414   50      146.53  356.93  559.57  78.74   535.99  0.3
40 24.5464429855   100     151.77  360.97  550.41  87.44   535.99  0.2
41 33.213009119    150     150.66  359.21  560.96  87.65   536.0   0.0
42 42.3064424992   200     152.61  361.77  560.39  92.74   535.99  0.3
43 51.392932415    250     148.20  358.2   559.73  105.43  536.0   0.0
44 60.4444475174   300     150.11  359.69  562.98  99.45   535.99  0.2
45 69.7904472351   350     147.40  356.77  548.18  97.24   535.99  0.2
46 78.6989281178   400     149.2   359.9   565.64  99.14   535.99  0.2
47 87.94343853     450     149.0   357.94  554.27  99.91   535.99  0.3
48 97.1684365273   500     139.73  347.69  567.51  98.78   535.99  0.2
49 106.324954987   550     149.11  358.93  575.66  100.22  535.99  0.3
50 116.142441511   600     150.69  360.22  562.78  100.76  535.99  0.4
51 126.224469185   650     146.67  357.22  561.62  98.4    535.99  0.4
52 136.304481506   700     143.59  352.50  564.56  99.34   535.99  0.3
53 146.35494566    750     146.16  356.7   550.85  102.3   535.98  0.5
54 156.404940128   800     150.64  359.32  542.65  98.69   535.97  0.10
55 166.512443066   850     148.39  358.79  547.75  101.58  535.94  0.20
56 176.574934006   900     147.16  356.51  548.73  106.27  535.82  0.37
57 # Recieved KILL signal.
58 # Reason: Stop to correct drift of 610B electrometer.
59 # File closed at 2012-09-04 12:21:20.173950